Winter preparation

Winter preparation

A high efficiency heat pump can deliver 50-75% in energy savings compared to traditional energy sources. If you have a heat pump as heat source in your home, we have some general advice for you, before entering the cold season.

Here are 5 simple heat pump troubleshooting steps to help you achieve the best heating for your household during the cold season. Most of them you can do yourself in a matter of minutes!
Check the line pressure of the heating installation once a month. The external manometer must have the correct pressure. The pressure of the heating installation might differ from country to country but the most common setting is between 1 and 1.5 bar. If the value display is below 0.8, the water must be topped up. If the link heating system pressure is too low or you are not aware of your heating system pressure settings please contact your local installer.

Step 1: Check the brine level

It’s essential that the brine circuit is always filled with the correct fluid levels otherwise the heating installation may become damaged. The fluid level may also vary depending on the temperature of the heat source. Under no circumstances must the fluid level be allowed to drop so far that it is no longer visible in the expansion tank. If the brine level is too low please contact your installer.

Step 2: Clean the brine circuit strainer

The brine circuit’s strainer must be cleaned twice a year. To clean it: Switch off the heat pump; Remove the insulation around the filler cock; Turn the shut-off tap (A) to the closed position; Unscrew the cover (B) and remove it; Remove and rinse the filter (C); Reinstall the filter; Check that the O-ring (D) on the cover is not damaged; Screw the cover back into place; Turn the shut-off tap to the open position; Reinstall the insulation around the filler cock; Start the heat pump.

Step 3: Check the water level of the heating system

Check the line pressure of the heating installation once a month. The external manometer must have the correct pressure. The pressure of the heating installation might differ from country to country but the most common setting is between 1 and 1.5 bar. If the value display is below 0.8, the water must be topped up. If the heating system pressure is too low or you are not aware of your heating system pressure settings please contact your local installer.

Step 4: Clean the strainer for the heating system

The strainer must be cleaned twice a year. Have a cloth ready when opening the strainer cover as a small amount of water usually escapes. To clean the strainer: Switch off the heat pump; Turn the shut-off tap (A) to the closed position; Unscrew the cover (B) and remove it; Remove and rinse the filter (C); Reinstall the filter; Check that the O-ring (D) on the cover is not damaged; Screw the cover back into place; Turn the shut-off tap to the open position; Start the heat pump.

Step 5: Switch operation modes

In the OPERATION menu you can set the operating mode of the heat pump. Please make sure that before the heating season arrives your heat pump is in AUTO or HEAT PUMP mode. When changing operating mode, confirm your choice by pressing the right icon.

Contact

Heeft u vragen? Neem dan contact met ons op

Schrijf ons

Choose from the list...
We inform you that your agreement may be withdrawn at any moment by sending an email message... more
We inform you that your agreement may be withdrawn at any moment by sending an email message to our Data Protection Officer: info@thermia.com from the address that the agreement concerns. We inform you that you are not profiled. Your data will not be shared outside the European Economic Community or shared with multinational organizations. hide
We inform you that the administrator of the personal data provided in the form above... more
We inform you that the administrator of the personal data provided in the form above is Thermia AB based in Box 950 671 29 Arvika. Please send all your questions and doubts to our Data Protection Officer at info@thermia.com. Your data will be processed in order to reply to the question according to the provision that data processing is lawful if it is necessary to carry out an agreement or prior to entering it. If you agree to the above, your data will also be used to send marketing content. You can find full information about your personal data in our privacy policy. hide
* Mandatory field

GeoTherma bvba

0032 16 65 65 58

Ecoterm.be

0032 9 324 79 69